Power SPD Box
Power Lightning Protection Module
Network Signal SPD
Video Signal SPD
Audio Signal SPD
Control Signal SPD
Monitor SPD
Supply Power SPD
Other accesories
·  1
·  1
·  1
·  1
·  1


Supply Power SPD  

1000M POE SPD


. Introduction

POE network surge protection device is designed, manufactured, and tested in compliance with international standard IEC61643.1, Chinanational standard GB18802.1,And quality control of our product is in strict accordance with ISO9001.

It’s adopted in various kinds of low voltage devices like video devices, POE network switch, web camera and etc. It can prevent the devices from being damaged by induced over voltage and surge over current of the lightning strike.

. Features

Large discharge capacity, stable;

Low residual voltage, good protection;

Fast responding, nanosecond level;

Low insertion loss, good transmission

Easy installation and maintenance;

III. Technology parameters:

Model

JM-ES-RJ45

Protection Class:

Network signal

power

Nominal operating Voltage UnV

5V

48V

Maximum operating Voltage UcV

6V

60V

Nominal Discharge Current(8/20μs)InKA

1KA

Max. Discharge Current (8/20μs)ImaxKA

3KA

Line to Line Up(V)

15V

Line to Ground Up(V)

120V

Response Timens

25ns

Transmission rate(bps)

1000M

Insertion LossdB

0.5dB

Protected Core

1-8

Protection Mode

full protection

Interface Model

RJ45

Material of Outer Shell

Aluminum alloy

IP Rating ,IEC 60529/EN 60529 approved

IP20

Working Environment

Temperature-40℃+80℃Relative Humidity95%

Sizemm

132*75*36

.Product Installation:

 1. This product is installed between signal channel and protected equipment, the output end is connected with protection equipment.

 2. All wirings must be solid and be connected by electric.

 3. The earth terminal of SPD should be connected to earth ground, ground screw with terminal forks which is applied to connect grounding collection row and earth terminal of SPD, after connecting the ground wire well, be sure to tighten the screws. The grounding line:

BVR ≥ 2.5mm2, the length of the ground wire to grounding collection row should be less than 1 m. Lightning proof grounding should be consistent with lightning protection regulatory requirements, grounding wire should be as thick and short as possible, resistance should be less than 10Ω.

Home | About Us | Prodcuts | Applications Cases | Sales Network | Honors | Order Online | Contact Us

Copyright © 2013  Shenzhen Jiaming Lightning Protection Technology Co., Ltd.
  Add:7F,Beifangjunyi Business Center, Baoan, Shenzhen, Guangdong 

Contact Us:Miss Liu  Tel:18823851018  E-mail:lily97008@sina.com